Important Notices
This section describes the safety requirements that must be met when installing and using OmniGlove. OmniGlove is an electronic device for use in robot data collection and teleoperation systems. Before first use, read this manual carefully to fully understand the safety warnings and risks involved. All personnel must strictly follow every instruction and guideline in this manual during use.
1.1Safety Warnings and Operating Precautions
Do Not operate or store OmniGlove in a high-temperature or high-humidity environment.
Do Not operate or store OmniGlove in a flammable or explosive environment.
Do Not bring OmniGlove near an open flame or heat source.
Do Not pull forcefully on the wrist area, sensor modules or cables.
Do Not subject OmniGlove to excessive external force, bending, crushing or impact.
Do Not grasp heavy, hot, sharp, rough-surfaced or corrosive objects while wearing OmniGlove.
Do Not let OmniGlove come into contact with liquids or live electrical parts.
Do Not operate hazardous machinery while wearing OmniGlove. The company assumes no liability for any personal injury or property damage resulting from such use.
Do Not use OmniGlove as protective work gloves. OmniGlove is a data collection and teleoperation device and provides no protection against pinching, crushing or burns.
When teleoperating a robot with OmniGlove, also follow the safety requirements of the robot.
Do Not allow minors to operate OmniGlove unsupervised. If use is necessary, it must take place under the continuous supervision and guidance of a qualified adult.
Do Not allow personnel who have not received product safety training, or who are unfamiliar with the operating logic and safety requirements of the device, to perform powered operation or commissioning independently.
Do Not operate OmniGlove while under the influence of alcohol, while fatigued, or after taking medication that may impair judgment or reaction time.
Do Not allow persons with impaired mobility or cognitive ability to operate OmniGlove unsupervised.
Before use, make sure all cables and connectors are intact. If an abnormal condition such as a short circuit or overheating occurs, disconnect the power immediately.
Persons with a pacemaker or other implanted medical device should consult a physician before using OmniGlove.
1.2 Risk Assessment
Mechanical hazards: Crush injuries, abrasions, etc., caused by contact with sharp objects while wearing the glove, or by placing the hand within the range of moving parts of a robot or other equipment.
Electrical hazards: Electric burns or electric shocks caused by contact with live parts or the use of damaged cables.
High-temperature hazards: Skin burns, etc., caused by prolonged contact with hot objects or hot equipment surfaces while wearing the glove.
Noise hazard: No significant hazard identified.
Vibration hazard: No significant hazard identified.
Radiation hazard: No significant hazard identified.
Material/substance hazard: Prolonged wear may cause discomfort such as excessive warmth or an allergic skin reaction. If discomfort occurs, stop using the glove immediately and remove it.
Ergonomic hazard: Prolonged continuous wear during data collection may cause hand fatigue or strain. Plan the length of each session accordingly and take regular breaks.
Environmental hazard: No significant hazard identified.
1.3Warranty and After-Sales Service
OmniGlove is covered by a 6-month limited warranty. During the warranty period, if the device exhibits a defect due to manufacturing or material flaws after it has been put into service, we will provide the necessary spare parts for replacement or repair. The product warranty shall be void if the defect results from improper handling, failure to follow the information in this manual, or unauthorized disassembly of the Product. After the warranty period expires, we reserve the right to charge the customer for replacement or repair. Outside the warranty period, we shall not be held liable for any damage or loss arising from a defect in the device, including but not limited to lost production or damage to other production equipment.
The glove fabric is a wear part. Wear, pilling, deformation and stains resulting from normal use are not covered by the warranty.
Except for the operations expressly permitted in this manual, unauthorized disassembly of OmniGlove is strictly prohibited and will void the warranty provisions of the Hardware Sales Agreement. If any malfunction occurs, contact after-sales service personnel promptly.
Customers may separately purchase extended warranty services or OmniCare+ services. Contact the sales or customer service team for details.
1.4Disclaimer
We are committed to continuously improving the product reliability and performance, and therefore reserve the right to upgrade the product without prior notice. We have made every effort to ensure the accuracy and completeness of this Manual but shall not be held liable for any errors or omissions it may contain. Due to continuous product improvement, version updates, typesetting or printing, the content of this Manual may differ from the actual product. The actual product and the latest information released by the Company shall prevail. If you find any errors or omissions, please contact the Company.
Defects or malfunctions caused by the following circumstances are not covered within the scope of warranty:
Wearing the glove or connecting other control devices in a manner not specified in this manual;
Unauthorized disassembly or reassembly of the glove;
Use beyond the specifications or standards stated in this manual;
Damage caused by improper transportation;
Damage caused by accidents or collisions;
Natural disasters, including but not limited to fire, earthquakes, tsunami, lightning strikes, strong winds and floods;
Hot-plugging the glove-side harness connector while the glove is powered;
Any product damage or other loss caused by the use of non-specified tools, or by disassembly or assembly not performed according to the specified method. The operator shall bear all such losses.
We shall not be held liable for any loss or injury caused by the customer’s violation of this disclaimer. Before purchasing and using this product, please read this disclaimer carefully and make sure you agree with it.
1.5Maintenance and Care Instructions
To keep OmniGlove operating reliably over the long term, follow the maintenance and storage requirements below.
For long-term storage, lay the Product flat in a dry place at a suitable temperature, away from direct sunlight, corrosive gases, strong electromagnetic interference, open flames and heat sources.
During long-term storage, disconnect the communication and power cable harness. Do not leave the glove under load, bent, compressed or hanging for extended periods, and do not fold the tactile sensing areas or press on the EMF modules. Store the glove in its original packaging or in protective packaging with dust-proof and shock-resistant features.
Do Not expose unprotected OmniGlove to liquids (such as alcohol, water or beverages), dust, sand or corrosive substances. Avoid exposure to rain. If the glove comes into contact with any of these, disconnect the power immediately and check the connectors, sensor modules and cables.
Do not soak OmniGlove in water or spray cleaning liquids onto it. Do not clean the glove with alcohol, strong acids, strong alkalis, corrosive cleaners, volatile solvents or abrasive materials. To remove surface dust, wipe the glove with a clean, dry, soft cloth.
Perform regular maintenance and inspection to make sure the sensor modules, cables, connectors and other components are in good condition and to prevent hazards caused by aging or damage.
If the glove malfunctions, do not disassemble it yourself or force it to continue operating. Record the fault symptoms, time of occurrence, operating environment and any abnormal warnings, and contact after-sales service personnel promptly. Damage caused by unauthorized repair, disassembly or modification, or by the use of non-original spare parts, may void the warranty, and the user shall bear all related risks.
1.6Environmental Compliance & Disposal Declaration
This product falls under the category of Waste Electrical and Electronic Equipment (WEEE). Recycle and dispose of it in accordance with the WEEE Directive. Do not dispose of the product with household waste. At the end of its service life, take it to a qualified local electronic waste recycling facility, where professional sorting enables resource recovery and harmless disposal and reduces the potential impact on the environment.
This product complies with RoHS environmental protection regulations. The content of hazardous substances in all components is within the legal limits.
1.7Manufacturer Information
Manufacturer | Shanghai AGILINK Innovation Technology Co., Ltd. |
Address | Room 1107, 11F, No. 185 Tianping Road, Xuhui District, Shanghai, China |
Telephone | +86-21-20960883 |
Product Introduction
2.1Product Overview
OmniGlove is a smart data glove for robot data collection and teleoperation. It captures hand pose data in real time, and the Pro version also captures full-palm tactile data. Its thin, lightweight design supports long, continuous data collection sessions.
2.2Key Features
High-precision hand pose tracking: Six EMF modules track the five fingers and the wrist, with a position accuracy of 1.5 mm (typical) and an orientation accuracy of ≤3° (typical).
Unified wrist–hand kinematics: The wrist and fingers are solved in a single kinematic chain. No external wrist tracker is required.
Full-palm tactile sensing (Pro version only): 746 sensing points in 17 sensing regions, covering the distal, middle and proximal phalanges of the four fingers, the distal and proximal phalanges of the thumb, and the palm.
Pressure range: 0–20 N
Pressure resolution: 0.1 N
Activation threshold: 10 gf (≈0.1 N)
Spatial resolution: <3 mm
Output rate: 125 Hz
Magnetic interference resistance: Built-in magnetic distortion compensation, fused with IMU data, keeps tracking stable near motors, metal structures and other sources of magnetic interference. Tracking is drift-free, so long sessions require no recalibration.
Low latency: 10 ms motion-to-data latency at a 125 Hz output rate, meeting the real-time requirements of teleoperation.
Lightweight design: Glove net weight ≤100 g; total weight with cable ≤150 g. Comfortable for extended wear.
Data collection and teleoperation in one: Suitable for dexterous hand teleoperation, tactile data collection and human–robot interaction research.
2.3Product Specifications
Parameter | Specification |
Basic | |
Size | |
Net weight | Standard ≤90g,Pro ≤100g |
Total weight(with cable) | ≤150g |
Pose Tracking | |
EMF Modules | 6 |
Position Accuracy | 1.5mm RMS |
Orientation Accuracy | ≤3° RMS |
Output Rate | 125 Hz |
Motion-to-date Latency | 10 ms |
Kinematic Solving | Wrist and fingers solved in a single kinematic chain; no external wrist tracker required |
Magnetic interference resistance | EMF magnetic distortion compensation + IMU fusion |
Zero drift | Drift-free; no recalibration needed during long, continuous sessions |
Inertial Measurement Unit(IMU) | |
Quantity | 7 |
Sample Rate | 1000 Hz |
Accelerometer Range | ±16g |
Gyroscope Range | ±2000 °/s |
Tactile Sensor (Pro verison) | |
Sensor Type | Full-palm 1D force tactile sensor |
Sensing Points | 746 across 17 sensing regions, spatial resolution <3mm |
Coverage | Distal, middle and proximal phalanges of the four fingers; distal and proximal phalanges of the thumb; palm |
Pressure Range | 0-20 N |
Pressure Resolution | 0.1 N |
Activation Threshold | 10 gf |
Output Rate | 125 Hz |
Electrical and Interfaces | |
Power/Data Interface | USB, 5V DC |
Cable | Combined communication and power cable harness, USB-A (computer side) to XH2.54 (glove side) |
Accessory Ports | Wrist tracking port (4-pin); robot control joystick port (4-pin) |
Software and Data | |
Host Software | Windows |
Calibration | 6-step per-user calibration |
Output Data | 21 joint angles; 21 hand keypoint poses; 5 fingertip target poses; wrist orientation; tactile pressure data(Pro verison only) |
Data Formats | CSV recording; real-time UDP output; SDK supported |
Enviromental | |
Operating Temperature | -10 ~ 45 °C |
Storage Temperature | -10 ~ 70℃ |
Operating Humidity | < 80% RH,non-condensing |
Storage Humidity | < 90% RH,non-condensing |
2.4Dimensions
2.5Tactile Sensing Points Layout
OmniGlove has 746 tactile sensing points distributed across 17 sensing regions.
2.6LED Status Indicators
The indicator LED is located on the back of the hand. States are listed in order of priority, from lowest to highest. When multiple states occur at the same time, only the highest-priority state is shown.
Priority | Color | Pattern | Device Status | |
|---|---|---|---|---|
0 | - | Off | Powered off | |
1 | White ⚪ | Steady on | Operational | |
2 | White ⚪ | Blinking | Initializing | |
3 | Red 🔴 | Breathing(4s a cycle: 2s fade-in, 2s fade-out) | Factory mode | |
4 | White/Red⚪🔴 | Alternating blink, 1 Hz (white 500 ms, red 500 ms) | Fault: time synchronization error | |
5 | Red 🔴 | Rapid blink, 2 Hz | Fault: hardware error | |
6 | Red 🔴 | Steady on | Firmware update in progress. Do not disconnect the USB cable. | |
Fault details for Priority 4 and 5 are displayed in the host software.
Unboxing and Installation
3.1Packing List
OmniGlove Packing List | ||
|---|---|---|
No. | Item | Qty |
1 | OmniGlove gloves(pair) | 1 |
2 | Power/Communication USB cable harness | 1 |
3 | Tracker adapter bracket | 1 |
4 | Quick Start Guide | 1 |
5 | Quality Inspection Certificate | 1 |
Notes:
The table above lists all standard items included with the product. Please check the contents against this list after unpacking.
Optional accessories are not included in the standard packing list and can be purchased separately as needed. Customization is also available on request.
OmniGlove Optional Accessories | ||
|---|---|---|
No. | Accessory | Description |
1 | Robot Control Joystick | Developed by AGILINK. Used for remote control of a full robot. |
2 | Wrist tracking module | Developed by AGILINK. Measures the relative pose between the wrist and the back of the hand. |
3 | Wrist QR code module | Developed by AGILINK. Measures the relative pose between the wrist and the headband. |
3.2Connection and Wearing
The materials, tools and steps required to connect OmniGlove to a computer and use it are described below.
Required Materials and Tools
No. | Item | Qty |
1 | OmniGlove gloves(pair) | 1 |
2 | Power/Communication USB cable harness | 1 |
3 | Computer or host controller | 1 |
Prepare optional accessories separately if needed.
Hardware Connection
Connect the USB port on the glove to a USB port on the computer using the USB cable harness.
Once powered on, the indicator LED blinks white while the device initializes. When the LED turns steady white, the device is operational.
Launch the host software and connect the device. For details, see Section 6.3, Device Connection.
Wearing and Removing the Glove
Wearing the glove
Align each finger with its finger sleeve and pull the glove on from the palm side. Apply force at the palm. Do not pull on the wrist area.
Adjust the fingertips. Each fingertip EMF receiver should sit directly above the fingernail, snug but not tight.
Position the acquisition module at the center of the back of the hand and fasten the wrist strap so that it is secure without constricting the wrist. Leave enough cable slack so that the cable is not pulled when the wrist bends.
Removing the glove
Pull off each finger of the glove one at a time by its fabric. Do not pull on the EMF modules.
Important: After putting on the glove and before connecting it to the software:
Keep your fingers slightly bent and relaxed.
Do not cross the fingertip EMF modules or make a fist.
Installing a Tracker (Optional)
To use an external tracker for spatial tracking:
Remove the cover from the surface of the EMF module on the back of the hand.
Mount the adapter bracket onto the transmitter housing.
Secure the tracker to the adapter bracket.
Different tracker models may require different adapters.
Interface Information
4.1Electrical and Communication Interfaces

Port | Function |
USB communication and power port(XH2.54, 5-pin) | 5V power supply and USB 2.0 communication. Connects to a computer or host controller |
Wrist tracking port(4-pin) | Connects to the wrist tracking module (optional accessory) |
Robot control joystick port(4-pin) | Connects to the robot control joystick (optional accessory) |
Notes: The three ports look similar. Connect each cable to the port shown in the figure above. The wrist tracking port and the robot control joystick port are intended for AGILINK optional accessories only.
4.2USB Cable Harness
Use the USB cable harness (supplied with the glove) to connect OmniGlove to a computer or host controller. One end of the harness is a USB-A (male) connector, which connects to the computer or host controller. The other end is an XH2.54 (male) connector, which mates with the USB communication and power port (female) on the glove. The harness is 1.5 m long.
The pin assignment of the USB cable harness is as follows:
Pin | USB Signal | Type | Wire Color | Function |
|---|---|---|---|---|
1 | VBUS | Power | Red | Power supply input (+5 V) |
2 | D- | Data | White | USB differential data (−) |
3 | D+ | Data | Green | USB differential data (+) |
4 | GND | GND | Black | Power and signal ground |
5 | Shield | Shield | Gray | Cable shield against electromagnetic interference |
Coordinate Frame Definitions
5.1Data and Coordinate Frame Overview
OmniGlove uses different reference frames for input and output:
Input is expressed in the transmitter frame (TX frame). Every position and orientation the system receives is a measurement of a receiver (RX) relative to the transmitter (TX) on the back of the hand.
Output is expressed in the wrist frame. Hand keypoints, fingertip targets and wrist orientation are all referenced to the wrist frame of the current hand.
The system does not output global poses. The output does not include the position of the wrist or fingertips in the robot base, room or camera frame. If required, use an external tracker. See Section 3.2.4, Installing a Tracker.
The TX frame and the wrist frame are linked by per-user calibration:
Glove measurements (TX frame) ──per-user calibration──▶ Wrist frame ──▶ Joint angles / Keypoints / Fingertip targets
The reference frame and units of each data stream are listed below:
Data | Direction | Reference Frame | Format and Units |
Raw fingertip RX pose(per finger) | Input | TX | Position (m) + Euler angles (°), intrinsic ZYX, order [yaw, pitch, roll] |
Raw wrist receiver pose | Input (Optional) | TX | Same as above. Only orientation is used for wrist orientation output; The position is recorded only. |
Joint angles(21个) | Output | — (joint variable) | rad. For sign conventions, see Section 5.2.4. |
Hand keypoint poses(21个) | Output | Wrist Frame | Position (m) + unit quaternion (x, y, z, w) |
Fingertip target poses(5个) | Output | Wrist Frame | Same as above |
Wrist orientation | Output (conditional) | Wrist frame, relative to the calibrated zero | Unit quaternion (x, y, z, w) + rotation matrix |
5.2Coordinate Frame Conventions
General Conventions
Right-handed frames: All frames are right-handed orthonormal frames. Units and handedness follow ROS conventions (REP 103). The axes of the wrist frame are defined anatomically and differ from the ROS body frame convention, so a mounting transform is required when integrating with a robot.
Units: Lengths are in meters and angles in radians. The only exception is input Euler angles, which are in degrees.
Rotation representation: Outputs use unit quaternions in (x, y, z, w) order; inputs use Euler angles. Some software, such as MuJoCo, uses (w, x, y, z) order. Check the order when integrating.
Wrist Frame (Output Reference Frame)
The wrist frame is fixed at the root of the hand model and is shared by all outputs. Its axes are defined anatomically:
Axis | Direction | Left vs. Right Hand |
+X | Radial (thumb side) | Same |
+Y | Left hand: dorsal; right hand: palmar | Opposite |
+Z | Proximal (from the finger bases toward the wrist and forearm) | Same |
The wrist frames of the left and right hands are mirror images of each other. Only the +Y direction is reversed.
TX Frame (Input Reference Frame)
Axis | Direction | Left vs. Right Hand |
+X | Left hand: radial; right hand: ulnar | Opposite |
+Y | Distal (along the back of the hand toward the finger bases) | Same |
+Z | Dorsal (perpendicular to the back of the hand, pointing outward) | Same |
The table shows the nominal mounting orientation of the transmitter and fingertip receivers. Deviations caused by how the glove is worn are compensated automatically by per-user calibration. No manual correction is needed.
The wrist receiver is also measured in the TX frame. The system uses only its orientation; Its own axes do not affect output.
Joint Angle Sign Conventions
The 21 output joint angles are finger joint variables, not spatial coordinates. Each of the four fingers has 4 joint angles (MCP flexion, MCP lateral deviation, PIP flexion and DIP flexion), for a total of 16. The thumb has 5 (CMC rotation, CMC flexion, CMC abduction, MCP flexion and IP flexion).
The following sign conventions apply to both hands:
Joint | Positive(+) | Negative(−) |
Finger MCP, PIP and DIP flexion | Flexion (fingertip moves toward the palm) | Extension |
Finger MCP lateral deviation | Fingertip deviates toward the ulnar side (little finger) | Fingertip deviates toward the radial side (thumb) |
Thumb CMC rotation | Rotation toward opposition | Rotation away from opposition |
Thumb CMC, MCP and IP flexion | Flexion | Extension |
Thumb CMC abduction | Abduction | Adduction |
5.3Left and Right Hand Rules
Axis Mirroring
The left and right hands each have their own mirrored hand model, with separate calibration, joint limits and configuration. The differences between the two hands are built into the models and calibration, and no mirroring is applied at runtime.
Coordinate Frame | Left Hand | Right Hand |
Wrist frame (output reference) | X radial / Y dorsal / Z proximal | X radial / Y palmar / Z proximal |
TX frame (input reference, nominal) | X radial / Y distal / Z dorsal | X ulnar / Y distal / Z dorsal |
Fingertip receivers (nominal) | Same as TX frame | Same as TX frame |
The two coordinate frames differ between hands on different axes: in the wrist frame, +Y is reversed; in the TX frame, +X is reversed. This is because:
The transmitter is mounted in the same orientation on both gloves. Viewed from the back of the hand, the +X axis of the TX frame points to the right on both hands. On the left hand, this is the thumb side; on the right hand, it is the little-finger side.
The wrist frame is defined anatomically, so its +X axis always points toward the thumb.
As a result, left-hand data cannot be used as right-hand data simply by negating or swapping axes.
Joint Angle Sign Consistency
The same joint with the same sign represents the same anatomical direction. Both hands follow identical sign conventions for joint angles, so there is no need to negate the joint angles of either hand downstream.
For example:
Flexion: When the index finger of either hand bends toward the palm, the joint angle is positive.
Lateral deviation: When the index finger of either hand deviates toward the little finger, the joint angle is positive. Viewed from the back of the hand, these two motions are in opposite directions in space: leftward on the left hand and rightward on the right hand.
Note: During flexion, the fingertip coordinates change in different directions in each hand’s wrist frame: the left fingertip moves toward −Y and the right fingertip toward +Y. This is because +Y points in opposite directions in the two wrist frames. Physical motion is the same.
Data Interchange Restrictions
Restriction | Description |
Calibration files cannot be used across hands | Each hand’s calibration file can only be used with that hand. If the calibration file of the other hand is loaded, the system reports an error and does not fall back to another file. |
Raw data cannot be solved across hands | Raw data from each hand must be processed with that hand’s own calibration file. It cannot be converted by negating or swapping axes. |
5.4Coordinate Frame Hierarchy
Overall Hierarchy
The system boundary is the wrist. Everything distal to the wrist frame, including the palm and all five fingers, is inside the system. Everything proximal to the wrist, including the forearm, body, robot, room and cameras, is outside the system.
[World / Robot base / Camera] Outside the system; integrated by the user
▲
│ Tracker's own tracking system
[External tracker (optional, mounted Outside the system
on the back of the hand)]
▲
│ Mounting transform (calibrated by the user)
[Wrist frame] ★ System root; reference frame for all outputs
├── Hand model hierarchy (see Section 5.4.2)
└── Glove sensor hierarchy (see Section 5.4.3)
Hand Model Hierarchy
Wrist frame ★
├── Transmitter mounting reference (for display only) [Pending confirmation]
└── Palm
├── Thumb: CMC → MCP → IP → Tip
├── Index finger: MCP → PIP → DIP → Tip
├── Middle finger: MCP → PIP → DIP → Tip
├── Ring finger: MCP → PIP → DIP → Tip
└── Little finger: MCP → PIP → DIP → Tip
Glove Sensor Hierarchy
The sensors are attached to the wrist frame through two types of relationships: per-user calibration, which remains fixed once calibrated, and per-frame measurement, which updates in real time.
Wrist frame ★
└── TX frame (back-of-hand transmitter) ← Per-user calibration; fixed once calibrated
├── Five fingertip receivers ← Per-frame measurement
└── Wrist receiver (optional) ← Per-frame measurement
Output Keypoints
The 21 output keypoints correspond to the joints and fingertips in the hierarchy above. All are expressed in the wrist frame.
Keypoint | Anatomical Location | Remarks |
Wrist | Wrist frame origin | Always an identity pose. Serves as a reference marker, not a measurement. |
Thumb CMC / MCP / IP / TIP | Carpometacarpal joint / Metacarpophalangeal joint / Interphalangeal joint / Fingertip | 4 points |
Fingers MCP / PIP / DIP / TIP | Metacarpophalangeal joint / Proximal interphalangeal joint / Distal interphalangeal joint / Fingertip | 4 points per finger, index to little finger. |
5.5Sensor Mounting Parameters
The tables below list the distances from the measurement center of the transmitter (TX) and of each fingertip receiver (RX) to each face of the housing. Use these values to build a custom hand model or to calculate the offset between the sensor measurement center and the surface of the hand.
Transmitter (TX)
Direction | Wrist Frame Axis | Reference Face | Distance |
Distal (toward the fingertips) | -Z | Front face of the housing | 28.70 mm |
Proximal (toward the wrist) | +Z | Rear face of the housing | 8.36 mm |
Radial (toward the thumb) | +X | Left face of the housing | 25.22 mm |
Ulnar (toward the little finger) | -X | Right face of the housing | 25.10 mm |
Dorsal (perpendicular to the back of the hand, pointing outward) | -Y | Top face of the housing | 2.91 mm |
Fingertip Receiver (RX)
Direction | Wrist Frame Axis | Reference Face | Distance |
Distal (toward the fingertips) | -Z | Front face of the housing | 11.84 mm |
Proximal (toward the wrist) | +Z | Rear face of the housing | 12.31 mm |
Radial (toward the thumb) | +X | Left face of the housing | 7.84 mm |
Ulnar (toward the little finger) | -X | Right face of the housing | 7.95 mm |
Dorsal (perpendicular to the back of the hand, pointing outward) | -Y | Top face of the housing | 2.05 mm |
Host Software Guide
Use the host software, OmniGlove Toolbox, to connect gloves, view and record data, run personal calibration, teleoperate dexterous hands, and update firmware. This chapter uses version 1.0.0 as an example. For other versions, use the matching file names. For the latest installation packages and instructions, refer to AGILINK’s official releases.
Release OmniGlove Toolbox v1.0.0 · AgibotTech/agilink_omniglove_toolbox
6.1Before you start
System Requirements and Installation Packages
OS | Installer | Portable | Launch |
Ubuntu 22.04/24.04 x86_64 desktop | .deb | .tar.gz | Application menu, or run run.sh |
Windows x64 | setup.exe | .zip | Start menu, or run OmniGloveToolbox.exe |
Download link : https://github.com/AgibotTech/agilink_omniglove_toolbox
macOS and ARM platforms are not supported.
Your computer needs a working desktop environment and OpenGL graphics driver. The 3D model and simulation windows rely on graphics rendering.
The installation package includes every component the software needs. You do not need to install Qt, Python, or an SDK separately. Prepare the glove driver, CAN adapter driver, and communication cables as your hardware requires.
Hardware Preparation
Prepare the glove for the hand side you will use, and a cable that supports data transfer. Seat the connectors firmly and keep the cable free of tension.
For two-hand use, prepare one left glove and one right glove. During calibration and teleoperation, connect only one glove per hand side.
Close any other program that uses the glove, including a second instance of Toolbox, SDK sample programs, and firmware maintenance tools.
Put on the glove as described in 3.2. Keep the sensors in place, and make sure your fingers can straighten, bend, and touch the thumb naturally.
When the first data arrives, keep the tactile areas free of contact for about 2 seconds so the software can zero them automatically.
For live teleoperation, also prepare a dexterous hand of a matching model, a power supply, communication cables, and an adapter. Leave room for the dexterous hand’s fingers to move.
Commonly Confused Terms
Terms | Meaning |
Detected | The software has found the glove. |
Connected | The software has opened a connection to the glove. |
Valid Data | The model, coordinates, or tactile display change with your movements. A static hand model alone does not mean data is arriving. |
Zero Pressure | Sets the current no-contact state as the tactile baseline. |
Recenter Pose | Uses the current hand pose as the reference for the displayed model. |
Reset View | Restores the default viewing angle. |
Personal Calibration | Fits the hand model to your hand. |
Saved/Written to glove | After calibration, the software first saves the result as a file. Teleoperation uses the new calibration only after the software writes it to the glove and the readback check passes. |
Zero Pressure, Recenter Pose, Reset View, and personal calibration each serve a different purpose. One cannot replace another.
6.Install, Update and Uninstall
Ubuntu Installer
Open a terminal in the folder that contains the installation package and run:
sudo apt install ./omniglove-toolbox_1.0.0-1_amd64.deb
When installation finishes, search for “OmniGlove Toolbox” in the application menu and open it. You can also run the following in a terminal:
/opt/omniglove-toolbox/run.sh
The installer sets up USB permissions for the glove automatically, so you can start the software as a regular user. If the software does not detect the glove, unplug and reconnect the glove, then click Refresh in Device Settings.
Ubuntu Portable
Extract the full package and run it for the first time:
tar -xzf omniglove-toolbox-1.0.0-linux-x86_64.tar.gz
cd omniglove-toolbox-1.0.0-linux-x86_64
sudo share/udev/install-usb-rules.sh
./run.sh
The third command sets up USB permissions. Run it once per computer. After that, run
./run.shfrom the same folder.
CAUTION
Keep every extracted folder (lib, bin, share, and so on). Do not copy the executable on its own.
Do not start the software with sudo in place of setting up USB permissions.
If the terminal reports that a file cannot be found, check the current folder and make sure the version number in the command matches the file name.
Windows Installer
Double-click
omniglove-toolbox-1.0.0-windows-x86_64-setup.exe. Follow the prompts to choose a language and installation folder, and approve the administrator request.If another version is already installed, the installer offers to upgrade, reinstall, or downgrade. Check the version number and installation folder before you continue.
When installation finishes, open “OmniGlove Toolbox” from the Start menu.
Connect the glove. In Device Manager, check that the glove uses the WinUSB driver. The installer does not install or change USB drivers.
Windows Portable
Extract omniglove-toolbox-1.0.0-windows-x86_64.zip in full to a folder you can write to, then double-click OmniGloveToolbox.exein the root folder. The portable version also needs the WinUSB driver and the adapter driver.
CAUTION Keep every DLL, model, and runtime file in the folder. If files are missing, extract the official package again in full. Do not copy individual DLLs from another version’s folder.
TIP Install the CAN adapter driver as instructed by the adapter manufacturer. Before the dexterous hand’s communication driver is ready, you can still connect the glove, view data, and run simulations.
Update the Software
Before you update
Stop teleoperation and calibration. If a recording is in progress, click Stop and Save. If a firmware update is in progress, wait for it to finish.
Exit Toolbox and the simulation window, and close any firmware maintenance tools.
Back up your calibration files, recordings, and any logs you want to keep. Note the glove SN, firmware version, and dexterous hand connection settings.
Install the new version
Installer: run the new installer. Portable: extract the new package to a new, empty folder.
After you update
Open the new version and check the version number at the bottom of the sidebar. Rescan the devices, then check hand opening, finger bending, tactile responseᴾ, and a short test recording.
TIP Updating the software does not update the glove firmware or recalibrate the glove. Software updates, firmware updates, and personal calibration are separate tasks.
Uninstall
Version | How to Uninstall |
Ubuntu Installer | Run |
Ubuntu Portable | Run |
Windows Installer | Uninstall from the system Apps list or the Start menu, or run |
Windows Portable | Run |
Uninstalling removes only the program files. Your personal data stays on the computer by default, but back up important files before you uninstall. USB and CAN drivers are not removed with the software. Uninstall them separately if needed.
6.3Interface Overview and First Use
Interface Layout
Area | Description |
Left sidebar | Lists the pages in three groups: Data Views, Operations, and System. The software version appears at the bottom. |
Top bar | Shows the current mode (live or playback) and device status. Use it to switch appearance and language. |
Workspace | Shows the content of the current page. |
Group | Page | Use | Check on First Use |
Data View | Pressure | View per-point tactile data, region totals, trend curves, and slip direction. | Tactile data is valid. Readings return to baseline with no contact. |
Model | Shows the 3D hand model and tactile points, and compares magnetic compensation results. | The model follows your finger movements. | |
Trajectory | View fingertip positions, coordinates, and motion trajectories. | The left and right hand windows match your actual movements. | |
Operations | Calibration | Complete the six calibration poses, then verify, save, and write the calibration to the glove. | Calibration hand side, save folder, and quality messages. |
Teleoperation | Select a dexterous hand model and run a simulation or control a real hand. | Model, hand side, run mode, and connection settings. | |
Firmware | View device versions, verify firmware files, and update firmware. | Target device, firmware type, and version. | |
System | Settings | Detect, connect, and disconnect devices, view device information, and change the interface appearance. | Hand side, UID, SN, and connection status. |
Logs | View records and diagnostic information for the current session. | Error messages, sources, and times. |
In Settings, go to Appearance to choose a light or dark theme and adjust Layout Density and Text Size. Changes take effect immediately. In a small window, some areas collapse or need scrolling. If you cannot find a button, expand the related area first.
First Use
Start the software and check the version number at the bottom of the sidebar.
Connect one glove, open Settings, and click Rescan Devices.
Check the detected device, then click Connect on its device card. If the list shows only the devices you want to use, you can also click Connect All Devices.
Keep the tactile areas free of contact for about 2 seconds. Then open Pressure and lightly touch each finger to check the response.
Open Model. Slowly open your hand, bend your fingers, and touch each fingertip to your thumb. Check that the model follows your movements and shows the correct hand side.
Open Trajectory and move your fingers. Check that the fingertip coordinates and trajectories change with your movements.
If the glove already has calibration and tracking looks correct, you can start recording or simulation. If you need a personal calibration, complete it as described in 6.5 and write it to the glove.
Before you start collecting data, record a short test motion. Stop and save the recording, then play it back to check the data and the file.
6.4Detect and Connect Devices
Detect Devices and Check Device Information
Open Settings and click Rescan devices. When detection finishes, the Detected Devices list shows a device card for each glove:

Information | Description |
Name and hand side | The device name, and whether it is a left or right glove. |
UID | Identifies each device. |
SN | The device serial number, used for device records and after-sales service. |
Hardware Version / Firmware Version | The device’s current hardware and firmware versions. |
Nominal Sampling Rate | The device’s design sampling rate. It does not indicate the screen refresh rate or the actual valid frame rate. |
If the software cannot read an item, the card shows No Device Found or an error message. Check the connection status and the logs (see 6.12) to find the cause.
TIPOn first use, note the SN and firmware version of each glove for future maintenance and after-sales service.
Connect One or Two Gloves
One glove: click Connect on the device card.
Two gloves: check the left and right gloves, then click Connect on each card. If the list shows only the devices you want to use, you can click Connect All Devices instead.
Once connected, every page uses the same connection. You do not need to connect again on each page. To end a connection, click Disconnect on the device card.
CAUTION
If more than one glove on the same hand side is connected, check the hand side and SN on each card so you do not mistake a spare glove for the one you intend to use.
During calibration, Write to Glove, and teleoperation, connect only one glove per hand side.
While recording or running a task, some connection buttons are unavailable. Stop the task and save your work before you change connections.
Check the Connection
A device card showing Connected means only that the connection is open. Check that the data is valid in this order:
Check the hand side and connection status on the device card.
Move your fingers. Check that the Model follows your movements, and that the coordinates and trajectories in Trajectory update.
Lightly touch your fingers. Check that the matching areas change in Pressure.
If a page shows Waiting for Data or Hold Pose, the connection may be open, but the page has not yet received the valid data it needs.
TIPThe standard glove has no tactile sensors, so an empty tactile page is normal and does not mean the glove is disconnected. The Standard glove supports Hand Model, Motion Trajectory, and teleoperation.
6.5Calibration
Six-step calibration fits the hand model to the shape of your hand. Hand Model and teleoperation both use it. Calibrate one hand at a time by following the on-screen guide through six poses.
When to Calibrate
Calibrate again when you:
Use a glove for the first time.
Change the wearer.
Adjust the sensor positions.
See the model consistently deviate from your actual movements when you open your hand or touch fingertips to your thumb.
You do not need to calibrate each time you start the software. First check how well the glove’s current calibration tracks your hand, and recalibrate only if you see clear deviations.
Before You Start
Calibrate away from metal, magnets, magnetically permeable objects, and electronic devices such as computers and phones.
Remove rings, watches, and other jewelry before you calibrate.
You can connect both gloves at once, but connect only one glove to the hand side you are calibrating. For your first calibration, connect only the glove you are calibrating so you do not select the wrong device.

Area | Desciption |
Current Action / Start Calibration / Stop | Shows the current pose number. Starts or stops calibration. |
Glove Status | Shows the connection status of the left and right gloves. |
Import Existing Calibration | Import existing calibration file, choose the hand side, and write to the glove. |
Calibration Settings | Select the calibration hand, set the calibration root folder, and view the output folder for this session. |
Pose guide | Shows the hand illustration, name, and instructions for the current pose. |
Steps
Stop teleoperation and recording, and exit playback.
Open Calibration. Under Calibration Settings, select Left or Right. If the settings area collapses, click Change Calibration Settings to expand it.
Check the Calibration Root. To change it, click Select and choose a folder you can write to with enough free space.
Check the Run Output Folder. Each calibration is saved separately by hand side and capture time, so earlier results are not overwritten.
Put on the glove and relax your palm and wrist, then click Start Calibration. The software connects to the glove for the selected hand side and starts capturing.
Calibration Poses
Follow the on-screen guide through the six poses in order. Each pose advances automatically once it meets the requirements.
Step | Illustration | Motion | Key Points |
1 |
| Flat | Straighten your fingers naturally and hold still. Avoid tensing, shaking, or visibly bending your fingers. |
2 |
| Four fingers flexion | Starting with your four fingers straight, bend them toward your palm at the base joints, then straighten them again. Do this twice in a row. Keep the other finger joints as straight as you can, and keep your palm and wrist still. |
3 |
| Thumb–Index Opposition | Lightly touch the pad of your index finger with the pad of your thumb and hold steady. |
4 |
| Thumb–Middle Opposition | Fully release the previous pair, then lightly touch the pad of your middle finger. |
5 |
| Thumb–Ring Opposition | After fully releasing, touch lightly when the next instruction appears. Avoid touching other fingers at the same time. |
6 |
| Thumb–Little Opposition | Touch fingertips naturally as shown, and hold steady without pressing. |
TIP
For pose 2, complete the full straight → bent → straight motion. Holding only the bent position will not complete the capture.
For opposition poses, touch lightly with your finger pads, not your nails, and do not press hard to line up the contact.
If the message Release Fingers First appears when you switch poses, separate your thumb from all fingers and wait for the next instruction before touching the next finger. Do not keep pinching the previous finger while moving to the next one.
Progress and Quality Messages
Message | What to Do |
Checking Current Pose | Hold the pose and wait for the check to finish. |
Retry / Insufficient Data / Unstable/Restarted | Adjust your pose as the message suggests. Do not rush to the next pose. |
Progress for the current pose resets to zero | This is normal. The software has discarded data that did not meet the requirements, so it does not enter the calibration result. Complete the current pose again. |
Reaching 100% on a single pose does not mean calibration has succeeded. After all six poses, the software fits the data and runs an overall check. Calibration is complete only when this check passes. If the overall check fails, start calibration again.
Save the Results and Write to the Glove
When the overall check passes, the software saves two files with the same name in the candidates folder of this session’s output folder: an
.ogcalcalibration file and an.urdfpersonal hand model.Once both files are saved, the page shows Calibration Complete, Files Saved. Click Open Results Folder to view and back up the files.
To make the glove use the new calibration right away, click Write to Glove. Keep the glove connected and wait for the write and readback check to finish.
When the page shows Calibration Written to Glove, Readback Check Passed, open Model or Teleoperationto check the result.
Straighten your fingers naturally, do four-finger base flexion, and do all four opposing poses. Check that the left and right hands are not swapped and that tracking looks correct.
Saving the .ogcal file alone does not update the calibration in the glove. You must click Write to Glove. POST Model Calibration on the Model page adjusts only the model displayed on your computer, and does not replace Write to Glove either.
Failure, Stop, and Retry
Situation | What to Do |
Files are saved, but writing to the glove fails | Check the target glove and connection, then click Retry Write to Glove. You do not need to repeat the six poses. Keep the .ogcal and .urdf files. |
You need to stop during capture | Click Stop and wait for the status to change and the glove to be released. Capture that has not passed the overall check cannot be used as a valid calibration. You can leave any generated files in this session’s output folder for troubleshooting. |
Calibration fails repeatedly | Check in this order: the sensors are secure, the poses are complete, the correct hand side is selected, and only one glove per hand side is connected. If calibration still fails, check the Calibration Log (see 6.12). |
6.6Pressure
The Pressure page shows where and how hard each hand is touching, in real time. You can also view region totals, trend curves, and slip direction. This section applies only to the Pro version.

Area | Description |
Record and Save / Open Recording | Record tactile, model, and trajectory data together, or open an existing recording (see 6.9). |
Color Scale | Select the color display range: 0–64, 0–128, or 0–255. |
Force Info | Shows total force values and trend curves for each region. |
Slip Detection | Shows the slip direction on the contact surface. |
Zero Pressure | Sets the current no-contact state as the tactile baseline. |
Clear Chart | Clears the existing trend curves and starts recording again from now on. |
Status | Shows live or playback status, sampling rate, and frame count. |
Tactile Sensor Map | Shows one tactile map for each hand, along with its connection status. |
Zero Pressure
The glove zeroes itself automatically once valid data arrives. Right after connecting, keep the tactile areas free of contact for about 2 seconds. Do not hold an object, press on the table, or press the sensors with your other hand.
If the display stays highlighted or shows visible background noise with no contact, zero the glove manually:
Remove all external force and keep your hand still.
Click Zero Pressure.
Lightly touch a few different areas. Check that the background is clear and that each area responds correctly.
Do not zero the glove while holding an object. The current contact would become the baseline and affect all readings that follow.
You cannot zero the glove during playback. Click Return to Live first, then zero.
Tactile Sensor Map and Color Scale
Each glove has 746 tactile points. The page always shows both hands, and a hand that is not connected appears as a gray outline. Use the per-point map to see where contact happens, how large the contact area is, and how its intensity changes.
The color scale sets how sensitive the colors are. Choose 0–64, 0–128, or 0–255. Changing the color scale changes only how colors are displayed. It does not change the sensor range and does not force calibration.
The lowest band is not colored and appears dark gray. Other bands follow the color scale. Dark gray can mean either no data or a very low value, so check the page status to tell them apart.
Each number on the color bar is the lower limit of that band. Hover over a band to see its full range.
Tactile point values and color bands are not values in newtons and cannot be used as force readings. For region totals and other force information, refer to the units shown on the page.
Force Info and Trends
Select Force Info to view total force values and trend curves for each region. Start by lightly touching a single fingertip, then touching other regions one at a time to check that the actual contact matches the regions shown on the page.
Button | Description |
Match Hand Scales | Uses the same scale for both hands’ curves for easier comparison. |
Freeze Charts / Resume | Freezes the charts so you can read specific values. The tactile map and data capture keep updating. Click Resume when you finish. |
Clear Chart | Clears the existing curves and starts recording again from now on. It does not zero the pressure. |
To record tactile, model, and trajectory data together, click Record and Save (see 6.9).
Slip Detection
Select Slip Detection, keep contact, and slide slightly. A bright magenta arrow shows the direction. The software estimates slip direction from changes in the tactile distribution, so interpret the result alongside the actual contact.
The slip arrow may not appear steadily if there is no valid tactile data, the contact is too light, your hand moves only in the air, or the contact barely changes. First confirm that the local tactile area responds, then check slip.
6.7Model
The Model page shows your hand movements on a 3D model in real time. Use it to check tracking, review joint angles, and compare magnetic compensation results.

Area | Description |
Also Export BVH / Record and Save / Open Recording | Record data and export a BVH file at the same time, or open an existing recording (see 6.9). |
Hand side | Show both hands, the left hand, or the right hand. |
Reset View / Zero Orientation | Restores the default viewing angle. Uses the current wrist orientation (and back-of-hand IMU flip, if enabled) as the reference for the displayed model. |
Model Options / Focus View | Expands the model settings area. Hides the surrounding controls and shows only the models. |
Model windows | One window for each hand. The top shows the data source, and the status line at the bottom shows the data status. Click Maximize to enlarge one hand. |
Check Tracking
By default, the model shows the joint angles, bone lengths, and orientation output by the glove (POST). Keep the default settings, then open your hand naturally, bend your fingers, and touch each fingertip to your thumb. Check that the model matches your actual finger movements.
The left and right windows correspond to the left and right gloves. If only one glove is connected, the other side shows the initial model. If a glove disconnects or its data becomes invalid, the model may stay in its last hand pose, and the status line shows Holding Last Pose. Check the connection and data status in the window to judge whether tracking is working.
View and Display
Rotate and zoom: drag with the left mouse button to rotate. Scroll to zoom.
Reset View: restores the default viewing angle.
Maximize: enlarges one hand’s model. Click Exit Maximize or press Esc to return.
Focus View: hides the surrounding controls.
Hand side: show both hands, the left hand, or the right hand.
Zero Orientation / Initial Hand Pose: Recenter Pose uses the current hand pose as the display reference. Restore Initial Hand Pose returns the model to its initial hand pose.
CAUTION Zero Orientation and Initial Hand Pose affect only the model display. They do not replace personal calibration or Write to Glove.
6.8Trajectory
The Trajectory page shows the positions, orientation axes, and motion trajectories of all five fingertips, and lists each fingertip’s coordinates.

Area | Description |
Connect Hand Group / Connect | Select which glove to connect (both hands, left, or right), then connect. |
Show Trails / Clear Trails | Shows or clears the trajectory history. |
Reset | Restores the default viewing angle. |
Record and Save / Open Recording | Records data from all views together, or opens an existing recording (see 6.9). |
Trajectory windows | One window for each hand, showing the five fingertip keypoints, orientation axes, and trajectories. Click Maximize to enlarge one hand. |
Fingertip Coordinates (mm) | Lists the X, Y, and Z coordinates of the five fingertips. |
View Positions and Trajectories
Open Trajectory and check the connected hand side and the status of each hand. Connect Hand Group sets which glove to connect. The page always shows both views.
Slowly bend, straighten, and move your fingers. Watch the five fingertip positions and trajectories change.
Read the values in Fingertip Coordinates (mm) at the bottom right of each window.
The views use the wrist frame (see Chapter 5). The wrist is fixed at the origin, −Z points up, and the grid spacing is 25 mm.
CAUTION The coordinates in this view are fingertip positions relative to the wrist. They do not show how the hand moves through space. To use these coordinates in a robot’s world frame, transform them first.
Recordings from earlier software versions may be missing some wrist or orientation data. As long as the five-finger data is valid, a missing marker does not mean the connection failed.
Common Operations
Clear Trails: trajectories become dense after continuous movement. Clear them, then repeat a small movement to observe it.
Rotate and zoom: drag with the left mouse button to adjust the view. Scroll to zoom. Click Reset to restore the default angle.
Check both hands: move each hand separately and check that each window matches the correct hand side.
Compare during playback: during playback, Trajectory, Pressure, and Model share the same timeline. Pause, then switch pages to compare pose, fingertip positions, and tactile distribution at the same moment.
6.9Record and Play Back Data
Pressure, Model, and Trajectory share one recording control bar. A single recording saves the data from all three pages together in one .ogrecord file. During playback, you can view the data on all three pages, so you do not need to record each page separately.
What Gets Recorded
A recording contains only the data the software actually receives:
The standard glove has no tactile sensors, so its recordings contain no tactile data.
If only one glove is connected, the recording has no valid motion data on the other hand.
Start and Stop Recording
Connect the glove and check that the pages you need show valid data. Stop calibration, teleoperation, and firmware updates, and exit playback.
On any data page, click Record and Save. Choose a save folder and enter a name for the .ogrecord file.
When the page shows Recording and the elapsed time, start the movements you want to record.
You can switch between the three data pages while recording. The recording continues unaffected.
When you finish, click Stop and Save and wait for saving to complete. Then open the file to check it.
TIP
Include the wearer or sample ID, hand side, movement, and date in the file name, for example user01_left_pinch_20261030.ogrecord.
Do not save important files in the software installation folder. Use your personal documents or a dedicated data collection folder.
Before a full session, record a short 10–20 second sample. Check that the folder is writable, the data is valid, and saving and playback both work, then start long recordings.
CAUTION Always end a recording with Stop and Save. If the software closes unexpectedly, the current recording may not be saved.
Play Back a Recording
Stop and save any recording, and end the current device task.
Click Open Recording and select an .ogrecord file. Playback does not require a connected glove.
Check that the control bar shows File Playback, along with the duration, frame information, and file path.
Click Play or Pause. Drag the timeline slider to jump to a specific moment.
Switch between Pressure, Model, and Trajectory to compare data at the same moment.
When you finish, click Return to Live before you resume live recording, Zero Pressure, or other device tasks.
CAUTION
Pause stops the timeline of the entire recording. Freeze Charts freezes only the trend curves on the Tactile Map page. They do different things.
The hand pose and tactile data shown during playback come from the file. They do not indicate that a glove is currently connected
6.10Teleoperation and Simulation
Teleoperation uses glove data to drive a dexterous hand. You can control the left hand, the right hand, or both: the left glove controls the left dexterous hand, and the right glove controls the right one. There are two running modes:
Simulation: runs in a MuJoCo simulation window. No dexterous hand needs to be connected.
Live Run: controls a real dexterous hand.
Both modes need valid glove data.
WARNING
A dexterous hand may start moving as soon as a live run starts. Before you start, make sure nothing is near the dexterous hand and the operator can stop the device with hardware at any time.
Do not change the model, hand side, or communication cables while teleoperation is running. Stop teleoperation before you adjust any settings.

Area | Description |
Dexterous Hand | Select the dexterous hand model. |
Start Teleoperation / Stop | Starts or stops teleoperation. The run status appears next to the buttons. |
Recalibrate | Opens the Calibration page. |
Connection status and control latency | Shows the connection status of each hand and the control latency for each side. |
Basic Settings | Select the model version, hand side, and run mode. For a live run, also enter the dexterous hand’s connection settings. |
Advanced Settings | Advanced parameter settings. |
Runtime Diagnostics | Shows the time spent at each processing stage |
Glove Input Recording and Playback | Records and plays back .ogteleop files (see 6.10.5). |
Supported Dexterous Hands
Device | Version | Joints | Notes |
OmniHand 3 | - | 10 active joints | Check the connection settings for one or two hands. |
OmniHand 3 Ultra | T1.5 | 21 independent joints | The version must match the actual hardware, or the model you want to simulate. |
OmniHand 3 Lite | - | 4 active joints; the last three fingers move together | The last three fingers moving together is part of the mechanical design, not a fault. |
If your software offers a Teleoperation Algorithm option, choose SDK Algorithm for regular use. Python Sync Algorithm is for specific trial environments, and whether it runs depends on what your software package includes. For basic use, complete connection, calibration, and simulation checks with SDK Algorithm first.
Check Movements in Simulation First
End any recording or calibration. If playback is running, click Return to Live.
Open Teleoperation and select dexterous hand model accordingly.
Select Left, Right, or Both, and make sure only one glove is connected to each selected hand side.
Set Run Mode to Simulation.
Click Start Teleoperation. The software connects to the selected gloves and opens the MuJoCo simulation window.
Slowly open your hand and bend your fingers, then touch each fingertip to your thumb. Check that the simulated hand follows.
In two-hand mode, the window shows the left and right hands side by side. Move each hand separately and check that the hands are not swapped.
When you finish, click Stop in Toolbox and wait for teleoperation to stop and the simulation window to close.
Simulation window controls
Drag with the left mouse button: rotate the view
Drag with the right mouse button: pan the view
Scroll: zoom
Press R: reset the view on the side under the mouse pointer. In two-hand mode, each side is controlled separately.
TIP After the page shows started, keep checking that the simulated hand follows your movements. If glove data is invalid or stops updating for a long time, the simulated hand may freeze in its last pose or stop responding. Check the glove status and the Teleoperation Log.
Check Before a Live Run
Confirm that movements work correctly in simulation (see 6.10.2).
Check the dexterous hand’s model, hand side, power supply, communication settings, and current hand pose.
Leave room for the dexterous hand to move, and have a hardware emergency stop ready.
For your first live run, test with no load, at low speed, and with small movements.
Start a Live Run with One or Two Hands
One hand
Select the model and hand side, and set Run Mode to Live Run.
Enter the dexterous hand’s connection settings.
Click Start Teleoperation. Start with small movements and check that the glove, the dexterous hand’s status, and its response are all correct.
Two hands
Select Both, then enter the connect specs under Left Robot and Right Robot. The two sides must not point to the same dexterous hand:
If both sides use the same CAN adapter, use a different channel for each side. You can also use a separate adapter for each side.
If you connect over serial, use a different serial port for each side.
If both sides use the same SocketCAN interface, use a different device ID for each side.
If Left/Right Connection Conflict appears, change the settings and wait until both sides are ready before you start.
While running and when finished
While teleoperation runs, watch the glove data, the dexterous hand’s connection status, and the control latency for each hand. To finish, click Stop and wait for the status to change to Stopped or Standby before you disconnect any hardware.
Glove Input Recording and Playback
The Teleoperation page can record glove input on its own and save it as an .ogteleop file. During playback, the software uses the current algorithm to recalculate the dexterous hand’s movements. An .ogteleop file is different from the .ogrecordfile in 6.9, and each opens from its own entry point:

File | Contents | Where to Open |
| Tactile, model, and trajectory data | Open Recording on either page in Data Views (see 6.9) |
| Input data from the gloves selected during teleoperation | Open Action Recording on the Teleoperation page |
Record glove input
Start teleoperation in simulation or live run mode, and check that the glove input and movements are valid.
Click Record Glove Input and choose a save location. Check that the recording time and input frame count are increasing.
When you finish, click Stop Recording and Save . Stopping teleoperation also saves the recording automatically, but for formal data collection, still check the save message and the file.
TIP The Record glove input / Stop and save button in the top-right corner of the simulation window uses the same recorder as this page. If you start recording from the simulation window, the file is saved automatically to your Documents folder. In two-hand mode, only one set of recording buttons appears, and it records input from both gloves.
Play back a motion file
Stop any teleoperation and recording. Click Open Action Recording and select an
.ogteleopfile. Playback does not require a connected glove. The dexterous hand model, Ultra version, and hand side are read from the file.In the playback panel, select Simulation or Live Run, and set the Joint Speed Limit (0.01–15 rad/s) and Start Ramp-Up time (0–5 s). For a live run, check the dexterous hand’s connection settings in the playback panel, and set them separately for each hand.
Click Start Playback. Use Pause, Resume, and Stop to control it. The progress bar shows progress only and cannot be dragged to jump to a point.
When you finish, click Close Action Recording.
WARNING Live playback drives the dexterous hand. Before you start, check the model, hand side, connection settings, and space for movement. Pause does not cut power and cannot replace a hardware emergency stop.
CAUTION
During playback, the software recalculates movements using the current algorithm and settings. After a software update or settings change, played-back movements may differ from the original recording.
.ogteleop files from earlier versions can still be opened, but they lack the keypoint orientation and thumb flexion data that newer versions record. Thumb rotation and contact may look different from newer recordings.
You can record an .ogrecord file while recording glove input. Before you play back an .ogteleop file, end any current teleoperation and recording. During playback, you cannot calibrate, write to the glove, or update firmware.
6.11Firmware Update
Use the Firmware Update page to update the glove firmware over USB. You can update the main controller, the nodes, or both.
WARNING
Use only official firmware files supplied by AGILINK that match your glove hardware.
Once the update starts, it cannot be canceled. During the update, do not unplug the cable, cut power, close the software, force-quit the process, or let your computer sleep.

Before You Update
Get the official firmware file that matches your glove hardware (BIN or HEX format), and check the version number and update notes.
Stop recording, calibration, and teleoperation, and exit playback. Keep the USB connection and power supply stable.
Note the current firmware version, hardware version, and SN, and back up your personal calibration.
Open Firmware Update and click Refresh to view the USB device and its current version.
TIP For your first update, connect only the glove you are updating. If several devices are connected, identify the target device by its USB port and device information.
Firmware updates run over a wired USB connection (DFU mode), not over the network.
Select the Device, Target, and File
Under USB Device, select the glove to update. In normal mode, refreshing shows the device’s current version. If the device is already in DFU mode, the current version may not be readable.
Select the Update Target and the matching firmware file:
Update Target | Firmware File to Select |
Main Controller | Main controller firmware |
Nodes | Node firmware |
Nodes + Main Controller | One main controller firmware file and one node firmware file. The software updates the nodes first, then the main controller. |
CAUTION Do not swap the main controller and node firmware files. BIN and HEX are only file formats. You cannot tell from the file extension whether a file is for the main controller or the nodes.
Verify and Write
Click Verify and Write. The software checks the firmware file and shows its version, build information, and file size. To check the file only, click verify Firmware.
When validation passes, the button changes to Verified and Write. Click it, then review the target device, update target, and firmware information again.
If everything is correct, confirm the update in the review window that appears.
CAUTION
If you change the device, update target, or firmware file, verify again.
Passing verification only means the file is intact. It does not mean the file is right for this glove. Use the update notes to confirm that the firmware version matches the target device.
During and After the Update
During the update
Once you confirm the update, the glove enters DFU mode automatically, and the page shows the update stage, progress, elapsed time, and log. After writing starts, the Cancel button turns gray and the update cannot be canceled. This is normal and does not mean the page has frozen. Check the progress and log to confirm the update is still running.
After the update
Wait for the device to return to normal mode.
Open Device Settings, rescan and reconnect the glove, and check the new firmware version.
Check hand opening, finger bending, tactile responseᴾ, and a short test recording.
CAUTION If the device stays in DFU mode or the update reports an error, save the update log and contact AGILINK Technical Support. Do not keep retrying the update.