This section describes the important notices that must be observed during the installation and operation of OmniHand 3 Lite (Small). As OmniHand 3 Lite (Small) is partly completed machinery, it is essential to carefully read this manual and fully understand the relevant safety warnings and potential risks prior to first use. All relevant personnel must conduct a risk assessment before each installation of OmniHand 3 Lite (Small) and strictly adhere to all instructions and guidance in this manual during operation.


1.1Safety Warnings and Operating Precautions

  • Do Not operate or store OmniHand 3 Lite (Small) in any high-temperature or high-humidity environment.

  • Do Not operate or store OmniHand 3 Lite (Small) in a flammable or explosive environment.

  • Do Not bring OmniHand 3 Lite (Small) near an open flame or heat source.

  • Do Not use OmniHand 3 Lite (Small) in any strong electromagnetic fields, such as near high-voltage power lines or high-power machinery.

  • Do Not apply excessive force on the fingers. Do Not forcibly pull the dexterous hand.

  • Do Not subject OmniHand 3 Lite (Small) to excessive mechanical load or shock.

  • Do Not use OmniHand 3 Lite (Small) to grasp any object that is excessively heavy, overheated, sharp, rough or corrosive.

  • Do Not touch the surfaces of OmniHand 3 Lite (Small) during or shortly after operation, as they may become hot and cause burns.

  • Do Not allow minors to operate OmniHand 3 Lite (Small) unsupervised. Where use is necessary, it must take place under the continuous supervision and guidance of a qualified adult.

  • Do Not perform powered operation or commissioning without having received product safety training and being familiar with the operating logic and safety rules of the equipment.

  • Do Not operate OmniHand 3 Lite (Small) under the influence of alcohol or fatigue, or after taking medication that impairs judgment or reaction time. Do Not allow persons with impaired mobility or cognitive ability to operate OmniHand 3 Lite (Small) unsupervised.

  • Do Not operate any hazardous machinery with OmniHand 3 Lite (Small). The company assumes no liability for personal injury or property damage resulting from such actions.

  • Before operation, make sure all cables, plugs, and sockets are intact. Disconnect the power supply immediately if an abnormal condition occurs, such as a short circuit or overheating.


1.2Risk Assessment

  • Mechanical hazards: Crush injuries, abrasions, etc., caused by contact with OmniHand 3 Lite (Small) or any sharp object being held.

  • Electrical hazards: Electric burns or electric shocks caused by contact with live parts.

  • High-temperature hazards: Burns caused by prolonged contact with hot surfaces of OmniHand 3 Lite (Small).

  • Noise hazard: No significant hazard identified.

  • Vibration hazard: No significant hazard identified.

  • Radiation hazard: No significant hazard identified.

  • Material/substance hazard: No significant hazard identified.

  • Ergonomic hazard: Pinch injuries caused by contact with gaps between components.

  • Environmental hazard: No significant hazard identified.


1.3Warranty and After-Sales Service

OmniHand 3 Lite (Small) is covered by a 6-month limited warranty. If any defect due to manufacturing or material flaws occurs after the Product is put into use, we will provide necessary spare parts for replacement or repair. The product warranty shall be void if defects result from improper handling, failure to follow the instructions provided in the manual, or unauthorized disassembly of the product. Without prejudice to the terms of this warranty, if the Product has exceeded its warranty period, we reserve the right to charge customers for the cost of replacement or repair.

Beyond the warranty period, if the device exhibits any defect, we shall not be held liable for any damages or losses incurred, including but not limited to production losses or damage to other production equipment.

Except for the operations expressly permitted in this manual, unauthorized disassembly of the Product is strictly prohibited. Otherwise, the warranty-related clauses in the Hardware Sales Agreement will become invalid. If any malfunction occurs, please contact after-sales service personnel promptly.

Customers may separately purchase extended warranty services or OmniCare+ services. Please contact the sales or customer service team for details.


1.4Disclaimer

We are committed to continuously improving the product reliability and performance, and therefore reserve the right to make product improvements or upgrade without further notice. We strive to ensure the accuracy and completeness of this Manual but shall not be held liable for any errors or omissions it may contain. Due to ongoing product improvements, version updates, or typesetting and printing, the content of this Manual may differ from the actual product. The actual product and the latest information released on our official website shall prevail. Defects or malfunctions caused by the following circumstances are not covered within the scope of warranty:

  1. Failure to install, wire or connect other control devices as required by the user manual;

  2. Unauthorized disassembly/assembly of OmniHand 3 Lite (Small);

  3. Use of OmniHand 3 Lite (Small) beyond the specifications or standards stated in the user manual;

  4. Damage resulting from improper transportation;

  5. Damage caused by accidents, impacts, or collisions;

  6. Damage caused by natural disasters, including but not limited to fire, earthquake, tsunami, lightning strikes, strong winds and floods;

  7. Hot-plugging of power or signal cables while the dexterous hand is powered on is not supported. Users must follow the specified operating procedures; the customer shall bear the corresponding responsibility for any fault caused by hot-plugging that does not comply with these requirements;

  8. Any product damage or other loss caused by the use of non-specified tools, or by disassembly or assembly not performed according to the specified method, shall be borne by the operator.

We shall not be held liable for any loss, damage, injury or expense caused by customers violating the disclaimers in this Section. Customers are kindly requested to carefully read and agree to this disclaimer before purchasing and using the Product.


1.5Maintenance and Care Instructions

To ensure the long-term stable operation of OmniHand 3 Lite (Small), please follow the maintenance and storage requirements below.

  • For long-term storage, it is recommended to store the product in a dry environment with suitable temperature, away from direct sunlight, corrosive gases, strong electromagnetic interference, fire sources, and heat sources.

  • During long-term storage, disconnect the power cable and communication cable. Avoid keeping the dexterous hand under continuous load, bending, compression, or suspended conditions for extended periods. It is recommended to use the original packaging or protective packaging with dust-proof and shock-resistant features for storage.

  • Without proper protection, OmniHand 3 Lite (Small) must not come into contact with liquids (such as alcohol, water, beverages), dust, or corrosive substances. Avoid exposure to rain. If accidental contact occurs, immediately disconnect the power supply and inspect the interfaces, joints, and housing condition.

  • Do not directly wash, soak, or spray cleaning liquids onto the dexterous hand. Do not use alcohol, strong acids, strong alkalis, corrosive cleaners, volatile solvents, or abrasive materials to clean the dexterous hand. A clean, dry soft cloth may be used to wipe the surface of the rigid housing to remove dust.

  • Regular maintenance and inspection should be performed to ensure that components such as motors and power systems operate normally, preventing potential hazards caused by aging or damage.

  • If the dexterous hand malfunctions, do not disassemble it yourself or continue forced operation. Record the fault symptoms, occurrence time, operating environment, load conditions, and abnormal warnings, then contact after-sales service personnel promptly. Damage caused by unauthorized repair, disassembly, modification, or use of non-original spare parts may invalidate warranty coverage. Related risks shall be borne by the user.


Product Introduction


2.1Product Overview

OmniHand 3 Lite (Small) is a durable dexterous hand. Small and lightweight, it combines tactile sensing, multi-gesture interaction, and data-collection-friendly design, and serves as a standard hand for humanoid robots. It is suited to robot commissioning, entertainment and commercial performances, and human–robot interaction, and handles everyday tasks such as carrying trays, picking up cups, holding props, and handing over objects.


2.2Key Features

  • Lightweight Weighs no more than 350 g, with dimensions of 140 × 71 × 32 mm, sized for small humanoid robots.

  • Drop-Resistant Has passed free-fall, pendulum impact, and horizontal end-impact tests. The hand withstands accidental robot falls and scrapes, reducing the need for repair and replacement.

  • Versatile Gestures Four active degrees of freedom drive 11 joints, with an open/close time of no more than 0.5 s, supporting common gestures such as fist bumps, handshakes, and thumbs-up.

  • Optional Tactile Sensing Tactile sensors are available as options for both the fingertips and the palm.

  • Multiple Control Modes Three control modes are supported: position control, hybrid force–position control, and hybrid force–position–velocity control.

  • Data Collection Ready Compatible with data collection devices such as Dex-UMI and data gloves, and supports a bracket-mounted fisheye camera.


2.3Basic Product Information

Product Model

OmniHand 3 Lite (Small) 

RoHS Certification

RoHS certified


2.4Product Specifications

  1. OmniHand 3 Lite(Small) Specifications

Parameter

Specification

Weight

≤ 350 g

Dimension

140 × 71 × 32 mm(L × W × T)

Active DoF

4

Total DoF

11

Opening/Closing Time

≤ 0.5 s

Fingertip Repeatability (Typ)

±0.5 mm

Grasping Capacity

1 kg(vertical grasp)

Operating Voltage

Normal 24 V (Range: 18–30 V)

Operating Current

Rated 1 A, Peak 3 A

Communication Interface

CAN-FD / RS485

Operating Temperature

-10 to 45 °C

Firmware Upgrade

OTA online supported

Tactile Sensor Specifications (Optional)

Force Sensing Type

1-D tactile (normal force)

Coverage 

All five fingertips and the palm; fingertip sides of the thumb and index finger

Force Resolution

0.1 N

Sensing Range

0–25 N

Safe overload (non-destructive)

75 N

  1. Joint Motion Range

Joint Motion Range Parameters

Finger

Joint

Motion Range (°)

Thumb

Side Swing

0–78

Flexion/Extension

0–50

Index

Flexion/Extension

0–80

Middle/Ring/Little

Flexion/Extension

0–80

[1] The parameters in the above tables may vary in application depending on the business scenario and product configuration; please refer to the actual product.

[2] The product appearance may be upgraded or adjusted in the future; please refer to the actual product at that time.


2.5Appearance Dimensions

The product appearance dimensions are shown below (unit: mm).


2.6Environmental Compliance & Disposal Declaration

This product is classified as Waste Electrical and Electronic Equipment (WEEE). When disposing of this product, please follow the requirements of the WEEE Directive.

The product must not be disposed of together with ordinary household waste. After the product reaches the end of its service life, it should be delivered to a qualified local electronic waste recycling facility for professional classification, recycling, and harmless disposal. Proper disposal helps recover valuable resources and reduces potential impacts on the ecological environment.

This product strictly complies with RoHS environmental protection regulations. The content of hazardous substances in all product components meets the legally defined limits.


2.7Manufacturer Information

Manufacturer

Shanghai Agilink Innovation Intelligent Technology Co., Ltd.

Address

Room 1107, 11th Floor, No. 185 Tianping Road, Xuhui District, Shanghai

Contact

021-20960883


Product Operation Guide


3.1Packing List

Packing List (Standard Items)

No.

Item

Qty

1

OmniHand 3 Lite (Small, Light/Right Hand)

1

2

Wrist adapter cable (Power & signal 2-in-1, bare-wire ends)

1

3

Quick Start Guide

1

4

Quality Inspection Certificate

1

5

Nylon-patch locking screws (M4*8 socket head cap screw)

7

6

Hex Key

1

7

Accessory bag(for hex key and screws)

1

Notes:

  • The table above lists all standard items included with the product. Please check the contents of this list after unpacking.

  • Optional accessories are not included in the standard packing list and can be purchased separately as needed. Optional accessories include: power adapter and power adapter cable, single-channel USB-to-CAN-FD adapter.


3.2Installation Guide

Follow the steps below to complete the installation:

STEP 1: Before installation, take out OmniHand 3 Lite (Small) (a right hand is used as an example), along with the five M4 × 8 socket head cap screws and the hex key from the accessory bag, as shown in Figure 1.

STEP 2: Plug the wrist adapter cable into the corresponding connector at the bottom of the wrist of OmniHand 3 Lite (Small).

STEP 3: Mount OmniHand 3 Lite (Small) onto the flange interface of the robot arm (an X2 arm is used as an example). Insert the five screws into the corresponding holes and tighten them with the hex key to a torque of at least 1.5 N·m, as shown in Figure 2. Figure 3 shows the completed installation.

Note:

  • When mounting OmniHand 3 Lite (Small) onto the flange interface, route the cable harness into the gap at the flange connection to prevent the cable from being crushed.


3.3Adapter Flange Reference (For X2)


3.4Common Troubleshooting

Issue

Solution

No communication via CAN-FD or RS485

Set the DIP switches at the bottom of the wrist to the required communication mode. See Section 3.5 for details.

Middle, ring, and little fingers do not flex in sync

Contact after-sales service to return the product for repair.

Screws loosen after being removed and retightened

The nylon-patch screws are single-use. Replace them with new screws after each removal.

Indicator light shows an error after power-on

Restart the device. If the error recurs, check the error message and troubleshoot using the SDK.

SDK troubleshooting

For common issues when driving OmniHand through the SDK, refer to: https://github.com/AgibotTech/agillink_omnihand_sdk/blob/main/doc/zh_cn/TROUBLESHOOTING.md

Host software troubleshooting

For host software issues such as firmware upgrade failures, refer to Section 6, Host Software User Guide.


3.5Operating Precautions

  • DIP switch settings: Select the communication protocol using the DIP switches at the bottom of the wrist.

    • Mode

      Switch 1

      Switch 2

      Switch 3

      Switch 4

      CAN-FD

      ON

      ON

      OFF

      OFF

      RS485

      OFF

      OFF

      ON

      ON

  • Commissioning, operation, and start/stop: These operations can be performed using the host software. See Section 6, Host Software User Guide.

  • Prohibited operations: 

    • Do Not manually bend the fingers when the dexterous hand has reached a joint limit.

    • Do Not manually bend the fingers while the dexterous hand is powered on.


Interface Information


4.1Mechanical Interface

d1a39e4c7eaca15e491a764351cc1d21.pdf

4.2Electrical and Communication Interface

  1. Operating voltage: 24 V (typ.)

  2. Input voltage range: 18–30 V

  3. Communication interface: CAN-FD / RS485, selected by DIP switches (default: CAN-FD). The DIP switch settings and the corresponding connector pin assignments are as follows:

    1. Mode

      DIP switch settings

      Pin 1

      Pin 2

      Pin 3

      Pin 4

      CAN-FD (default)

      1, 2 ON; 3, 4 OFF

      24 V

      GND

      CAN_H

      CAN_L

      RS485

      1, 2 OFF; 3, 4 ON

      24 V

      GND

      RS485_A

      RS485_B

  1. Connector Pin Identification

OmniHand 3 Lite (Small) uses the custom LVC015 connector series. The connector has a split design: the signal and power modules can be separated and recombined, allowing the connector to pass through small-diameter openings during routing. This simplifies installation, production, and maintenance.

Connector models: board side LVC015-M (male), cable side LVC015-F (female).

4.3 Debug Cable

The OmniHand 3 Lite (Small) can be connected using the debug cable harness supplied with the dexterous hand. One end of the harness is an LVC015-F (female) connector; the other end splits into a power cable and a twisted pair for CAN-FD or RS485 communication. The harness is 0.2 m long. The LVC015-F (female) connector mates with the LVC015-M (male) connector on the wrist side of OmniHand 3 Lite (Small).

Connect the power cable to a regulated DC power supply. The twisted pair is used to send and receive CAN-FD or RS485 data; the communication mode is determined by the DIP switch settings and can be changed as required during development.

The pin assignment of the debug cable harness is as follows:

LVC015 Pin

Definition

Type

Description

Wire Color

Function

1

Power+

Power

DC 18–30 V

Red

Power

2

Power-

Power

Ground

Black

3

CAN_H/485A

SIG

CAN_H/485_A

Blue

Communication

4

CAN_L/485B

SIG

CAN_L/485_B

White


Communication Protocol


5.1Frame Format

CAN-FD

Default configuration: arbitration phase at 1 Mbps (80% sample point) and data phase at 5 Mbps (75% sample point), using the 29-bit extended identifier data frame format. Standard identifiers and remote frames are not supported.

This device supports CAN-FD frame format only. For classic CAN 2.0 frames, the device will:

  • not parse the data

  • not send any acknowledgment

  • not generate error frames

Messages are assembled according to the CAN-FD frame format, with the payload distributed across the arbitration field and the data field: the device ID, project number, register address, and sub-register address are carried in the arbitration field, while the data content is carried in the data field.

The device ID, project number, register address, and sub-register address are carried in the arbitration field; the data content is carried in the data field.

CANFD Frame Format

Field

Identifier

Length

Description

Remarks

Arbitration Segment Standard ID

standard_identifier

11 bits

bit[10:6]: sub-register address Range: 0x00–0x1Fbit[5:0]: Upper 6 bits of the register address(see below for range)


Arbitration Segment Extended ID

extended_identifier

18 bits

bit[17:16]: Lower 2 bits of the register address; together with the lower 6 bits of the standard ID, these form the complete register address byte bit[15:8]: Fixed at 0x01bit[7]: r/w flag 0 = read register 1 = write register bit[6:0]: device ID Range: 0x00–0x7F

Device ID 0x00 is the broadcast address. A node receiving data with this ID still replies using its own ID.

Data field

data

n

Data content corresponding to the register


Serial/RS485 Frame Format

Field

Identifier

Length (bytes)

Description

Notes

Start of frame

sof

2

Fixed value that allows the receiver to quickly locate frame boundaries

Fixed at 0xAAEE

Device ID / Read-Write Flag

device_id/rw_flag

1

bit[7]: r/w flag Range: 0 = read register 1 = write register bit[6:0]: device ID Range: 0x00–0x7F

Broadcast address: 0x00. A node receiving data with this ID still replies using its own ID.

Product No.

product_id

1

Fixed at 0x01


Register Address

reg_addr

1



Sub-register Address

sub_reg_addr

1

Range: 0x00~0x1F


Data length

len

1

Length of the data field in bytes Range:0–255


Data field

data

n



CRC16

crc16

2

Checksum covering the start of frame through the end of the data field. See the Appendix for the calculation method.



5.2Register Description

No.

Register Address

Name

Sub-Register

Sub-Register Name

Description

Length

Access

Pn1

0x01

Manufacturer Information

0x00

All Sub-register

Reads all sub-registers under this register.

41 Bytes (padded to 48 bytes)

Read-only

0x01

Product Model

ASCII string, padded with 0x00; Example: "OmniHand 3 Lite"

16 Bytes

Read-only

0x02

Serial Number

Fixed-length ASCII string in the format "SSCMMVVYMXXXXX"SS: Product series, 2 characters; the first uses base-26 (A–Z), the second is decimal (0–9);C: Product configuration, 1 character, base-32 (0–Z) encoding;MM: Component number, 2 digits, decimal (0–9);VV: BOM version, 2 digits, decimal (0–9);Y: year of manufacturer, 1 character, base-26 (A–Z);M:month of manufacturer, 1 character, base-12 (1–C);XXXXX: Sequence number, 5 digits, decimal (0–9);

14 Bytes

Read-only

0x03

Hardware Version

Hardware version information;Byte 0: Major version number;Byte 1: Minor version number;Byte 2: Patch version number;Byte 3: Reserved;Hardware Version: 'Major.Minor.Patch';

4 Bytes

Read-only

0x04

Software Version

Software version information;Byte 0: Major version number;Byte 1: Minor version number;Byte 2: Patch version number;Byte 3: Reserved;Software Version: 'Major.Minor.Patch';

4 Bytes

Read-only

0x05

Supply Voltage

16-bit unsigned integer; default 24000 (24V); unit mV;

2 Bytes

Read-only

0x06

Active DoF

Example: 0x04, number of active degrees of freedom; value range 1, 32

1 Byte

Read-only

Pn2

0x02

Device Information

0x00

Sub-Register Operation

Reads/writes all sub-registers under this register;

5 Bytes

Read/Write

0x01

Device ID

Default device ID: 0x04; Range: 0x01 – 0x7F;

1 Byte

Read/Write

0x02

Communication Parameters

Byte 0: CAN-FD arbitration phase bit rate, 8-bit unsigned integer, default 0x02 (1 Mbps)

0: 125 kbps;

1: 500 kbps; 

2: 1 Mbps

Byte 1: CAN-FD arbitration phase sample point, 8-bit unsigned integer, default 0x01 (80.0%)

0: 75.0%; 

1: 80.0%; 

2: 87.5%

Byte 2: CAN-FD data phase bit rate, 8-bit unsigned integer, default 0x03(5 Mbps)

0: 125 kbps; 

1: 500 kbps; 

2: 1 Mbps; 

3: 5 Mbps

Byte 3: CAN-FD data phase sample point, 8-bit unsigned integer, default 0x00 (75.0%)

0: 75.0%; 

1: 80.0%; 

2: 87.5%

4 Bytes

Read/Write

Pn5

0x05

Downsampled Tactile Data

0x01

Thumb Fingertip Sensor

bytes0–bytes20 Tactile sensor point pressure values, unit g

21 bytes

Read-only

0x02

Index Fingertip Sensor

bytes0–bytes20 Tactile sensor point pressure values, unit g

21 bytes

Read-only

0x03

Middle Finger Sensor

bytes0–bytes19 Tactile sensor point pressure values, unit g

20 bytes

Read-only

0x04

Ring Finger Fingertip Sensor

bytes0–bytes15 Tactile sensor point pressure values, unit g

16 bytes

Read-only

0x05

Little Finger Fingertip Sensor

bytes0–bytes11 Tactile sensor point pressure values, unit g

12 bytes

Read-only

0x06

Palm Sensor

bytes0–bytes44 Tactile sensor point pressure values, unit g

45 bytes

Read-only

Pn6

0x06

Full 1-D Tactile Data

0x00

All Sensors

  • Query command (Robot to hand):

byte0: query type.

0x00 = read all sensor data

0x01 = Number of tactile sensors

0x02 = Total number of tactile sensor points

0x03 = Total data length 0x04 = Total number of response frames 

0x05 = reserved

  • Response (hand to robot)

byte0: total number of response frames. For example, 0x0A means 10 frames follow in succession, carrying all sensing point data in sensor order.

byte1: current frame index (0 to total frames-1)

byte2–byte63: datain sequence



0x01

Sensor 0

  • Query (Robot to hand):

byte0: query type

0x00 = read all data of sensor 0

0x01 = number of tactile sensor points on sensor 0

0x02 = data length of sensor 0

0x04 = number of response frames for sensor 0

0x05 = reserved

  • Response (hand to robot)

byte0: total number of response frames. For example, 0x0A means 10 frames follow in succession, carrying all sensing point data in order.

byte1: current frame index (0 to total frames-1)

byte2–byte63: data, in sequence



0x02

Sensor Data

Same as 0x01, subsequent sensors follow in order.



...





Pn11

0x0B

Tactile Sensor Calibration

0x00

Tactile Sensor Calibration

Write with no data (0 bytes) to start calibration.

Returns 1 if calibration succeeds, 0if it fails.

0 byte

-

Pn19

0x13

Position Control

0x00

Sub-Register Operation

Reads/writes all sub-registers under this register;

Single sub-register length × active DoF

Read/Write

0x01

#1 Joint Motor Target Position

16-bit signed integer; default 0; range 1/40962 bytes represent one joint motor;

The valid range depends on the product.

Write: sets the target position and returns the current actual position.

Read: returns the current actual position.

2 Byte

Read/Write

0x02

#2 Joint Motor Target Position

2 Byte

Read/Write

...

... ...

... ...

...

Pn20

0x14

Hybrid Position-Torque Control

0x00

Sub-Register Operation

Byte 0: joint ID and control mode. The upper 3 bits set the control mode; the lower 5 bits set the joint ID.

The data that follows depends on the joint ID and control mode in Byte 0. Current setpoint range: 0–255.

Data for multiple joints is packed in sequence and parsed by joint ID. If parsing fails, no response frame is returned.

Packet length per joint × number of active DoF

Write-only

0x01

Sub-Register Operation

(continued)

Same as 0x00. If the joint data exceeds 64 bytes of 0x00, the remaining joints are sent in 0x01.

-

Write-only

0x02

Sub-Register Operation

(continued)

Same as 0x00. If the joint data exceeds the 64 bytes of 0x00 and 0x01, the remaining joints are sent in 0x02.

-

Write-only


Host Software Guide


OmniHand-ToolBox is a general-purpose host software for the OmniHand Series. Use it to connect the hand, control its joints, program motion sequences, view tactile data and update firmware.

The left navigation bar has four pages: Home, System Log, Firmware Update and Settings, described in 6.4 to 6.7. Joint control, motion configuration, the 3D hand model and the tactile display are all on the Home page, in a single workspace.


6.1 System Requirements

Item

Requirement

Operating System

Windows 10 / 11 (64-bit); Ubuntu 22.04 LTS (64-bit)

CPU

Intel Core i5 8th generation or later 

Memory

8 GB or more

Display

OpenGL 3.3 or later (integrated graphics are sufficient). A resolution of 1920 × 1080 or higher is recommended. The Home page shows several panels side by side, and higher resolutions can show more panels at once.

Communication Hardware

Dual-channel USB-to-CAN-FD adapter (ZLG / HCAN), with its CAN-FD driver installed

Software Dependencies

The installer includes the Qt runtime libraries and the SDK. No separate Qt installation is required.

The host software communicates with the hand over CAN-FD. Install the driver for your CAN-FD adapter before use.


6.2Download and Installation

Download the OmniHand-ToolBox software package from the official website https://github.com/AgibotTech/agilink_omnihand_toolbox 

  1. Windows

  • Download and run the Windows installer, then follow the prompts. Installation creates shortcuts on the desktop and in the Start menu.

  • Double-click OmniHand-ToolBox to start the host software.

  1. Ubuntu 22.04 (.deb package)

  • To install, run the following commands in the directory that contains the .deb file. Replace the file name with the name of the file you downloaded.

sudo apt install ./omnihand-toolbox_<version>_<arch>.deb

Using apt install ./xxx.deb automatically resolves dependencies; after installation, you can find "OmniHand-ToolBox" in the application menu, or run omnihand-toolbox in the terminal to launch.

  • Uninstall:

sudo apt remove omnihand-toolbox

This manual corresponds to host software version v2.7.2 (the actual version is shown in the software title bar and in the "Host Software Version" line in the device information area of the Main Interface).


6.3Login

When the software starts, the login screen appears. The username and password are pre-filled as user / user. Click Loginto open the Home page; You do not need to enter anything.

To change the interface language, use the language drop-down list in the upper-right corner. Simplified Chinese and English are currently supported.


6.4Main Interface

  1. Interface Layout

After login, the Home page opens. From left to right, the window has five areas:

  • Navigation bar (left): Home, System Log, Firmware Update, Settings.

  • Device column (column 1): Quick Connect (see 6.4.2), hand motor diagram, Enable / Disable, display switches, device information (see 6.4.3), and the joint status matrix with polling (see 6.4.4).

  • Curve column (column 2): data acquisition switch and real-time curves (see 6.4.5).

  • Control column (column 3): control mode, anti-jitter, motion schemes and joint sliders (see 6.4.6).

  • Motion and visualization column (column 4): three tabs, Preset Motions, Custom Motions and Motion Sequences (see 6.4.7), with the 3D hand model and tactile display below (see 6.4.9).

Above the device information is a row of five display switches: Curves, Control, Motions, Model and Tactile. Clear a switch to hide its column and give the screen space to the other areas. Clearing Tactile also stops tactile data acquisition. On low-resolution screens, keep only the columns you need.

  1. Quick Connect

Power on the hand and connect it to the computer over CAN-FD through the USB-to-CAN-FD adapter.

  1. Select the detected CAN-FD device from the device drop-down list. If No device found is shown, click ⟳ on the right to refresh.

  2. Select the product model (OmniHand 3 Lite) and the hand side (Right / Left).

  3. Click Connect. After the handshake succeeds, the device information area shows the data read from the hand, and the button turns red and changes to Disconnect.

For more connection settings, such as the CAN device index and channel, go to the Settings page in the navigation bar (see 6.7).

Connection Troubleshooting: 

  1. No device in the device drop-down list (the computer does not detect the CAN-FD adapter): 

    1. Check that the USB-to-CAN-FD adapter is plugged into the computer and its driver is installed correctly.

    2. Click ⟳ to refresh.

    3. If no device appears, reconnect the adapter or try another USB port.

  2. A device is detected, but the status remains [Not Connected] (the hand does not respond): 

    1. Check that the hand is powered on.

    2. Check that the CAN cables and connectors are firmly seated.

    3. Check that the DIP switch is set to CAN-FD (factory default).

    4. On the Settings page, check that the correct CAN device index and channel are selected (see 6.7).

    5. Check that the correct product model and hand side are selected.

    6. If the problem persists, close the host software, reopen it and try again.

  1. Device Status and Enable

  • Hand motor diagram: shows where the four active joints are on the hand, numbered 1 to 4. The numbers match those in the joint status matrix and on the joint sliders.

  • Enable / Disable: sets whether the hand’s joints respond to control commands from the host software. When disabled, the joints no longer execute position commands.

  • Device information: shows eight items: Device Model, Host Software Version, Firmware Version, Hardware Version, Supply Voltage, DoF, Device ID and Serial Number. When the hand is not connected, every item except Host Software Version shows Not connected in red.

  1. Joint Status Matrix and Polling

The joint status matrix sits below the device information. It shows four real-time values for each joint, one joint per row: position, current (mA), temperature (°C) and error code. When the hand is not connected, each cell shows “--”.

  • Polling switch: when on, the software reads these values from the hand at the set interval. When off, the software stops sending periodic read requests. The matrix and the curves then keep the last values read and no longer refresh.

  • Interval (ms): the polling interval. The default is 300 ms. After changing it, click Confirm to apply. A shorter interval increases the bus load, so keep the default in most cases.

Click any value cell in the matrix to add that joint’s value as a real-time curve (see 6.4.5).

  1. Real-Time Curves

At the top of the curve column are the data acquisition options: Position, Current, Temperature and Error Code. Clear an option to stop updating that data; its curves freeze.

Below them is the curve toolbar:

  • Time window drop-down list: sets the time span of the horizontal axis. Choose from several presets between 1 s and 60 s.

  • Pause All / Resume All: pauses or resumes refreshing of all curves.

  • Clear All: clears all plotted data from every curve.

  • Add: opens the Add Curve dialog box. Select a joint and a parameter to add a curve. Available parameters include joint position, current, temperature, velocity, torque and error code. For tactile parameters, select a finger or the palm instead of a joint.

When no curves are shown, the curve area displays Click a parameter in the matrix on the left to add a curve. Each curve has its own buttons to pause, clear, zoom the vertical axis, reset the view and close that curve. Drag a curve to change its position in the list.

  1. Joint Control

The hand has four controllable joints. In the software they are listed from top to bottom as joints 1 to 4. For joint names and ranges of motion, see 2.4.2. The label above each slider is the joint’s name.

Control mode: three modes are available. After you switch modes, only the parameters that mode needs are shown and sent.

Mode

Parameters Sent

Description

Position

Position

Default mode. Controls only the target position of each joint.

Position + Torque

Position, Torque (mA)

Adds a limit on the joint’s torque current, in mA.

Position + Velocity + Torque

Position, Velocity (rpm), Torque (mA)

Also sets the joint’s rotational speed, in rpm.

Throttle (ms): the minimum interval between position commands sent to the hand while you drag a slider. After changing it, click Confirm to apply. At 0, every change of the slider is sent at once, and fast dragging produces a large number of messages. Above 0, one position command is sent per interval while you drag.

Motion scheme drop-down list: lists the custom motions available for the current hand side (left or right). Select one to move all sliders to the positions saved in that motion. The first item, None, selects no motion. To delete a motion, right-click it in the list, or click the ✕ that appears when you hover over it.

Execute: sends the positions of all sliders to the hand at once.

Function buttons:

  • Initialize: returns all joints to their initial positions at connection.

  • Save Motion: saves the current positions of all sliders as a custom motion. Enter a name when prompted. The motion then appears in the Motion scheme list. It is stored only in the software until you export it with Export Motion Library.

  • Export Motion Library: exports all custom motions in the motion scheme list to a .json file (see 6.4.8).

  • Import Motion Library: reads motions from a .json file and adds them to the motion scheme list. If the file contains motions with the same names as existing ones, a dialog box lists the motions that will be overwritten and asks you to confirm before importing.

Joint sliders: one row per joint. The joint name is at the start of each row. Below it are the position slider, the target value box and the current feedback value. Drag the slider to control the joint in real time, or type a target position in the box and press Enter. Position is given in motor position counts, from 0 to 4096 on this hand, covering the joint’s full physical travel. For the angle range of each joint, see 2.4.2.

  1. Preset Motion, Configured Motion, and Motion Sequence

The fourth column has three tabs at the top.

Preset Motions lists the fixed gestures built into the SDK: AllZero (all joints at zero), Fist and Open. Click a button to move the hand quickly into that pose. Built-in gestures cannot be modified.

Compose Motions chains custom motions together. Select motions from the motion scheme list one by one, and they run in order as a single group. You can also set the number of loops and record run data.

  1. Click Add to add a row. In the row’s drop-down list, select a motion and enter the interval (ms) to wait after it. Repeat to chain more motions in order. Delete rows as needed.

  2. Select Record to write run data to a CSV file while the motions run. The file path is shown to the right of the check box. If Record is not selected, the motions are played back without recording.

  3. Enter the number of loops in Repeat, or select ∞ to loop indefinitely.

  4. Click Start to run the motions in order. The number of completed runs is shown on screen. Click Stop to end.

Motion Sequence builds a sequence of steps:

  • Add Step: opens a dialog box. Under Select motion source, choose a custom motion or a built-in preset, enter Interval (ms), and click OK to add it to the end of the step list.

  • Count / ∞: sets how many times the whole sequence repeats, or select ∞ to loop indefinitely.

  • Play / Stop: runs the steps in order.

  • Import / Export: loads a sequence from a file, or saves the current sequence to a file.

  • Clear: removes all steps from the current sequence. A confirmation dialog box appears first.

  1. Motion Library File (JSON)

Custom motions in the motion scheme list can be saved to a JSON file with Export Motion Library (see 6.4.6), so you can reuse them later or move them to another computer.

To edit a motion file by hand: the file is a JSON array, and each motion is a JSON object enclosed in braces. Separate objects with commas. Each object has the following fields:

  • name: the motion name.

  • hand_type: optional. Set to left or right to show the motion only for that hand side. If left empty or omitted, the motion is shown for both hands.

  • pos_axis_N: the target position of each joint, where N is the joint number, starting from 1. This hand uses pos_axis_1to pos_axis_4. The value range is the same as for the joint sliders in 6.4.6.

[
 {
   "name": "Motion 1",
   "hand_type": "right",
   "pos_axis_1": 0,
   "pos_axis_2": 0,
   "pos_axis_3": 0,
   "pos_axis_4": 0
 },
 {
   "name": "Motion 2",
   "pos_axis_1": 2048,
   "pos_axis_2": 2048,
   "pos_axis_3": 2048,
   "pos_axis_4": 2048
 }
]

6.4.9 3D Hand Model and Tactile Display (Optional)

3D hand model: the title bar shows the connection status and the current hand side. On the right are two buttons, Calibrate and Reset View. A 3D model is not yet available for this hand, so the area stays blank after connection. We recommend clearing the Model switch at the top to give the space to the curves and tactile display. To see the real-time pose of each joint, use the hand motor diagram and the joint status matrix in the first column.

Tactile display (optional): tactile sensors are an option on this hand. If the hand has tactile sensors and the Tactileswitch is selected (default), this area shows real-time tactile data while the hand is connected over CAN-FD.

  • Region readings (left): six regions, Thumb, Index, Middle, Ring, Little and Palm. Each shows the total force currently on that region, in g. The color bar next to each value shifts from blue to red as force increases, so you can see at a glance which finger is in contact with an object.

  • Heat map (right): the same six regions, from top to bottom. Each cell is one sensing point in that region; the redder the cell, the greater the force at that point. The number of sensing points in each region is reported by the device and matches the specification of the installed tactile sensors.

If the hand has no tactile sensors, this area shows no data. Clear the Tactile switch to hide it.


6.5System Log

The System Log page records runtime information such as model initialization, connection, control mode changes, motion execution and firmware updates. The log scrolls to the newest entry automatically.

  • Com: select to log the details of data sent and received over the bus.

  • Data Recording: select to record run data to a CSV file. The file path is shown to the right of the check box.

  • Save Log: exports the current log to a text file.

  • Clear: clears the log display.


6.6Firmware Upgrade

The Firmware Upgrade page shares the connection and device information area in the first column with the Home page. On the right is the update area; The row at the top shows the firmware version, hardware version and serial number.

To update the firmware:

  1. Check that the hand is connected and not holding or carrying any load.

  2. Click Query Version to view the current firmware version, hardware version, serial number and other information.

  3. Click Start Upgrade and select the downloaded firmware file (.bin) to begin the update. Do not power off the hand or disconnect the CAN-FD connection during the process.

  4. Progress is shown in the log. Wait for the update to finish. When it succeeds, the log shows messages that the update is complete and the device is restarting.

  5. If the update fails, reconnect the hand as prompted and click Start Upgrade again.

Other buttons: Save Log (exports the log to a .txt file) and Clear Log.


6.7Settings (Device Connection)

The Settings page provides the full set of connection settings:

  • Product: select OmniHand 3 Lite.

  • Hand side: Right / Left.

  • Connection type: ZLGCAN or HCAN; SocketCAN is also available on Linux. All use CAN-FD. RS485 is not supported in the current version.

  • CAN index / CAN channel: must match the USB-to-CAN-FD adapter in use (default 0 / 0).

  • Use the switch on the right to connect or disconnect. The text to its left shows the current status: Not connected, Connecting…, Connection failed or Connected.

  • The software sends the CAN-FD communication parameters using the fixed values defined in Chapter 5. No manual setup is needed.

Once connected, the product, connection type and connection parameters are grayed out and cannot be changed. To change them, disconnect first. The hand side can still be switched while connected.


Unlock the resources